Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
J Aerosol Sci ; 152: 105693, 2021 Feb.
Article in English | MEDLINE | ID: covidwho-1392358

ABSTRACT

The COVID-19 pandemic has brought an unprecedented crisis to the global health sector. When discharging COVID-19 patients in accordance with throat or nasal swab protocols using RT-PCR, the potential risk of reintroducing the infection source to humans and the environment must be resolved. Here, 14 patients including 10 COVID-19 subjects were recruited; exhaled breath condensate (EBC), air samples and surface swabs were collected and analyzed for SARS-CoV-2 using reverse transcription-polymerase chain reaction (RT-PCR) in four hospitals with applied natural ventilation and disinfection practices in Wuhan. Here we discovered that 22.2% of COVID-19 patients (n = 9), who were ready for hospital discharge based on current guidelines, had SARS-CoV-2 in their exhaled breath (~105 RNA copies/m3). Although fewer surface swabs (3.1%, n = 318) tested positive, medical equipment such as face shield frequently contacted/used by healthcare workers and the work shift floor were contaminated by SARS-CoV-2 (3-8 viruses/cm2). Three of the air samples (n = 44) including those collected using a robot-assisted sampler were detected positive by a digital PCR with a concentration level of 9-219 viruses/m3. RT-PCR diagnosis using throat swab specimens had a failure rate of more than 22% in safely discharging COVID-19 patients who were otherwise still exhaling the SARS-CoV-2 by a rate of estimated ~1400 RNA copies per minute into the air. Direct surface contact might not represent a major transmission route, and lower positive rate of air sample (6.8%) was likely due to natural ventilation (1.6-3.3 m/s) and regular disinfection practices. While there is a critical need for strengthening hospital discharge standards in preventing re-emergence of COVID-19 spread, use of breath sample as a supplement specimen could further guard the hospital discharge to ensure the safety of the public and minimize the pandemic re-emergence risk.

3.
Advanced Materials Technologies ; : 1, 2021.
Article in English | Academic Search Complete | ID: covidwho-1267441

ABSTRACT

As a core part of personal protective equipment (PPE), filter materials play a key role in individual protection, especially in the fight against the COVID‐19. Here, a high‐performance multiscale cellulose fibers‐based filter material is introduced for protective clothing, which overcomes the limitation of mutual exclusion of filtration and permeability in cellulose‐based filter materials. With the hierarchical biomimetic structure design and the active surface of multiscale cellulose fibers, high PM2.5 removal efficiency of ≈92% is achieved with the high moisture transmission rate of 8 kg m−2 d−1. Through a simple and effective dip‐coating and roll‐to‐roll process, the hierarchical filter materials can be made on a large scale and further fabricated into high‐quality protective clothing by industrial production equipment. [ABSTRACT FROM AUTHOR] Copyright of Advanced Materials Technologies is the property of John Wiley & Sons, Inc. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)

5.
J Med Virol ; 92(9): 1518-1524, 2020 Sep.
Article in English | MEDLINE | ID: covidwho-2600

ABSTRACT

The outbreak of the novel coronavirus disease (COVID-19) quickly spread all over China and to more than 20 other countries. Although the virus (severe acute respiratory syndrome coronavirus [SARS-Cov-2]) nucleic acid real-time polymerase chain reaction (PCR) test has become the standard method for diagnosis of SARS-CoV-2 infection, these real-time PCR test kits have many limitations. In addition, high false-negative rates were reported. There is an urgent need for an accurate and rapid test method to quickly identify a large number of infected patients and asymptomatic carriers to prevent virus transmission and assure timely treatment of patients. We have developed a rapid and simple point-of-care lateral flow immunoassay that can detect immunoglobulin M (IgM) and IgG antibodies simultaneously against SARS-CoV-2 virus in human blood within 15 minutes which can detect patients at different infection stages. With this test kit, we carried out clinical studies to validate its clinical efficacy uses. The clinical detection sensitivity and specificity of this test were measured using blood samples collected from 397 PCR confirmed COVID-19 patients and 128 negative patients at eight different clinical sites. The overall testing sensitivity was 88.66% and specificity was 90.63%. In addition, we evaluated clinical diagnosis results obtained from different types of venous and fingerstick blood samples. The results indicated great detection consistency among samples from fingerstick blood, serum and plasma of venous blood. The IgM-IgG combined assay has better utility and sensitivity compared with a single IgM or IgG test. It can be used for the rapid screening of SARS-CoV-2 carriers, symptomatic or asymptomatic, in hospitals, clinics, and test laboratories.


Subject(s)
Antibodies, Viral/immunology , COVID-19/diagnosis , COVID-19/immunology , Immunoassay , Immunoglobulin G/immunology , Immunoglobulin M/immunology , SARS-CoV-2/immunology , Antibodies, Viral/blood , COVID-19/virology , Humans , Immunoassay/methods , Immunoglobulin G/blood , Immunoglobulin M/blood , Point-of-Care Testing , Reagent Kits, Diagnostic , Reagent Strips , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL